Closed - Major Incident #9074048654

POP Site Loss

Closed 7 years ago
Incident affecting: Northern Quarter, Manchester
 
We've lost connectivity to a POP in the Northern Quarter, engineers are investigating
 

Updates(most recent first)

  • Unfortunately the logs do not show any cause for the reboot event. All router heuristics look normal both before and after the event, traffic load was normal and there was no CPU/Memory/IO spike. The router is on UPS protected power and there is no indication of any abnormality in the supply.

    There is a pending software update for the device which we will be implementing in the next 2 weeks.

    We're also planning a maintenance window for this router in the next 2 months to do a full upgrade of the cabinet to improve airflow.

    Incident state changed to 'Solved'
    7 years ago - 4:45pm on 23rd February 2017
  • The downtime was caused by an aggregation router rebooting, we're investigating the root cause now and we will update this incident when complete.

    7 years ago - 1:34pm on 23rd February 2017
  • A potential fix has been implemented and our engineering team is now testing the system to make sure the issue has been successfully resolved.

    Incident state changed to 'Testing'
    7 years ago - 1:25pm on 23rd February 2017
  • This incident has been logged and our team is now working to diagnose and fix the problem.

    Incident created
    7 years ago - 1:23pm on 23rd February 2017